J41B NRS Ammonia Globe Valve

Product overview

Product model: J41B
Nominal diameter: DN15 ~ DN300
Nominal pressure: PN16 ~ PN25
Applicable medium: liquid, gas, ammonia, nitrogen, hydrogen
Applicable temperature: -10℃-150℃
Body material: cast iron, cast steel
Drive mode: manual, gear drive, electric, pneumatic, etc
Design and manufacture: GB12235
Structure length: GB12221
Flange size: GB9113 JB79
Pressure - temperature: GB9131
Test - inspection: GB/T13927 JB/T9092

J41B NRS Ammonia Globe Valve product details

J41B NRS Ammonia Globe Valve structural characteristics and uses
 1, through the flange for the square structure, the stem rod connection. 
 2, the valve body sealing surface using ball convex shape, and the valve to line seal. 
 3, the sealing surface with Babbitt, sealing performance, long service life.


The J41B NRS Ammonia Globe Valve produced and sold by Baigang Valve Group often uses oxygen, nitrogen, hydrogen, argon and other gases.These gases are generally stored in a special high pressure gas.When in use, the gas pressure is reduced to the range required by the experiment through the ammonia cut-off valve, and then the gas is input into the use system through other control valves.Commonly used pressure reducing valve for ammonia cut-off valve, referred to as ammonia valve.


J41B NRS Ammonia Globe Valve performance specifications

Nominal pressure PN (MPA)

Test pressure PS (MPa)

Suitable media

Applicable temperature (℃)

2.5

3.8

Ammonia, 
ammonia and other 
NH3

Babbitt alloy 
 -40 ℃ 
+ 150 ℃

PTFE 
-40 ℃ 
+200 ℃

4.0

6.4


J41B NRS Ammonia Globe Valve main size and weight:

DN (mm)

Size (mm)

L

D

D1

D2

D4

b

f

f1

Z-φd

turn off

open

D3

10

130

90

60

40

35

16

2

4

4-φ14

165

185

110

15

130

95

65

45

40

16

2

4

4-φ14

165

185

110

20

150

105

75

55

51

18

2

4

4-φ14

170

200

120

25

160

115

85

65

58

18

2

4

4-φ14

197

210

120

32

180

135

100

78

66

20

2

4

4-φ18

199

213

140

40

200

145

110

85

76

20

3

4

4-φ18

248

264

160

50

230

160

125

100

88

22

3

4

4-φ18

265

295

180

65

290

180

145

120

110

24

3

4

8-φ18

310

349

220

80

310

195

160

135

121

26

3

4

8-φ18

340

357

240

100

350

230

190

160

150

30

3

4.5

8-φ23

380

413

280

125

400

270

220

188

176

32

3

4.5

8-φ25

430

451

320

150

480

300

250

218

204

32

3

4.5

8-φ25

505

492

360

200

600

360

310

278

260

34

3

4.5

12-φ25

550

806

400

250

650

425

370

335

31

36

3

4.5

12-φ30

730

880

450

300

750

485

430

390

364

40

3

4.5

16-φ30

-

995

550


J41B NRS Ammonia Globe Valve appearance and working principle

 Ammonia valve high pressure chamber and the cylinder connection, low pressure chamber for gas exports, and access to the use of the system. Indication of high pressure gauge is the pressure of gas stored in the cylinder. Low pressure gauge outlet pressure can be controlled by adjusting screw. 
 Open the cylinder main switch when using, then turn the low pressure gauge pressure adjusting screw clockwise to compress the main spring and drive the diaphragm, spring pad and ejector to open the valve. Such imports of high-pressure gas from the high-pressure chamber after throttling decompression into the low-pressure chamber, and through the exit leading to the working system. Turn the adjusting screw to change the opening height of the valve to regulate the passage of high-pressure gas and achieve the desired pressure value. 
 Ammonia cut-off valves are equipped with safety valves. It is to protect the ammonia valve and make it safe to use the device, but also the ammonia valve failure signal device. If due to the valve pad, valve damage or for other reasons, resulting in the pressure on the outlet and rise above a certain allowable value, the safety valve will automatically open the exhaust.

Fifth, the use of
 (1) according to the different requirements of use, ammonia valve has many specifications. Most of the highest import pressure, the minimum import pressure of not less than 2.5 times the outlet pressure. Export pressure specifications more generally, the maximum outlet pressure.   
 (2) Ammonia valve should be installed to determine whether the connection specifications consistent with the use of the system connector. Ammonia globe valve with hemispherical connection, by tightening the nut so that the two completely match. Therefore, the use of the two hemispherical surfaces should be kept clean to ensure a good airtight effect. Use high-pressure gas to blow off the dust before installation. If necessary, PTFE and other materials can also be used for gaskets. 
 (3) ammonia valve should be prohibited from contact with grease, so as to avoid fire accidents. 
 (4) stop working, the relief valve should be more than air net, and then loosen the adjustment screw to prevent long-term compression of the elastic deformation. 
 (5) Ammonia stop valve should be avoided impact vibration, not with corrosive substances in contact.



Reminder:

All text, data and pictures in this article are for reference only.To see more details of the J41B NRS Ammonia Globe Valve performance parameters, structural dimension parameters, pricing, etc., or to request high quality printing samples, please Contact us.

+86-021-57278881
qrCode
主站蜘蛛池模板: 亚洲成av人片高潮喷水| 国产视频中文字幕| 国产在线精品99一卡2卡| 亚洲av无码成人网站在线观看| 3d动漫精品啪啪一区二区中文| 波多野结衣一区二区三区在线观看| 嫩b人妻精品一区二区三区| 公用玩物(np双xing总受)by单唯安| 丰满人妻熟妇乱又伦精品| 老师让我她我爽了好久动漫| 无遮挡韩国成人羞羞漫画网站| 国产xxxxx| 中国大陆高清aⅴ毛片| 久久久久亚洲精品中文字幕| 青青草原伊人网| 无码人妻精品一区二区三区蜜桃 | 男女一边摸一边做爽爽| 好爽好深好猛好舒服视频上| 免费无码午夜福利片69| 亚洲AV之男人的天堂| 青青草原国产视频| 最漂亮夫上司犯连七天| 国产婷婷综合丁香亚洲欧洲| 久久久久久亚洲精品不卡| 美女性生活电影| 好大好爽好舒服视频| 亚洲视频免费在线播放| 7777精品久久久大香线蕉| 欧美a视频在线观看| 国产午夜亚洲精品不卡免下载| 久久无码人妻一区二区三区| 自拍偷自拍亚洲精品播放| 很黄很色裸乳视频网站| 人人妻人人添人人爽日韩欧美| 8x国产在线观看| 日韩中文字幕在线播放| 台湾三级香港三级经典三在线 | 无码人妻精品一区二| 免费看美女隐私全部| 777米奇色狠狠888俺也去乱| 星空无限传媒xk8046|